Ironwood-electronics Mictor Connector Mating _ Un-mating Instructions Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Ironwood-electronics Mictor Connector Mating _ Un-mating Instructions. Ironwood Electronics Mictor Connector Mating _ Un-mating Instructions User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 1
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Tel: (800) 404-0204
www.ironwoodelectronics.com
This Ironwood Electronics document references AMP document 114-11004, Rev 0. PLEASE
REFERENCE THIS WHEN MATING AND UNMATING YOUR AMP CONNECTORS.
MICTOR SMT Connectors 114-11004
3.9. Mating and Unmating
The use of uneven or off-angle forces during mating and unmating of the connectors
could cause overstress and damage to the contacts andlor housings. Using the "peel-
back" method of unmating one end and pulling it until the other end is unmated is
permissible. Do NOT use a severe side-to-side rocking motion to unmate connectors.
Connectors must be pushed straight in when mating and pulled straight out when unmating. A slight end-
to-end motion may be used to start extraction, but it must not continue through full extraction cycle.
Miniaturization is a design feature of these connectors and the systems in which they are used.
Component density, connector location, and pc board size may make it difficult to remove the connector.
Two methods are recommended to facilitate removal. If unmating board-to-board connectors, the
preferred method is to have one of the pc boards securely fastened and adequately supported to
withstand the pulling force applied to the other pc board. The second method is to construct a tool for
your system design that will produce a straight-away separation of the connectors. See Figure 14.
CAUTION
Przeglądanie stron 0
1

Podsumowanie treści

Strona 1 - Tel: (800) 404-0204

Tel: (800) 404-0204 www.ironwoodelectronics.com This Ironwood Electronics document references AMP document 114-11004, Rev 0. PLEASE REFERENC

Komentarze do niniejszej Instrukcji

Brak uwag